What Happens When a Centrifuge Is Discontinued? A Buyer’s Checklist
Published November 20, 2026A centrifuge being discontinued doesn’t necessarily mean it needs to be replaced right away. The problem often becomes more apparent when a centrifuge needs repair and replacement parts, such as a rotor, lid latch, or control board are no longer available. Before deciding whether to repair or replace the equipment, it helps to understand what the discontinuation means for your specific model and what support remains available.
This checklist covers what to confirm, how to evaluate centrifuge repair options, and what to consider when selecting a replacement.
Confirm What “Discontinued” Means for Your Centrifuge
The term discontinued doesn’t always describe the same stage of a product’s lifecycle. A manufacturer might stop selling a centrifuge while continuing to offer replacement parts or service support. Both options can have separate end dates.
Contact the manufacturer or distributor to confirm three things:
- End of sale: When did the manufacturer stop selling the model?
- Parts availability: Are replacement parts still available, and is there a stated date when they will no longer be supplied?
- End of service: Is technical support or authorized repair still available? Has an end-of-service date been announced?
Make sure to have the centrifuge’s model and serial numbers available when contacting the manufacturer. This information can help identify the exact version of the equipment and clarify its current support status.
A discontinued centrifuge is not necessarily unsafe to operate. Continued use depends on its condition, maintenance history, and the availability of qualified service. The CDC’s guidelines for human and animal diagnostic laboratories emphasize that centrifuges must be properly maintained and operated, and that manufacturer instructions for the centrifuge and rotor should be followed.
The guidelines also note that older centrifuges may lack certain safeguards such as lid locks, imbalance detection, or overspeed protection, which makes assessing the equipment and its operating procedures even more important.¹
Check Centrifuge Parts and Repair Options
If your centrifuge needs repair, start by identifying the specific part or service required. Some centrifuge parts may remain available after a model is discontinued, but availability can vary by component.
Before committing to a repair, confirm:
- The replacement part number and whether the component is approved for your centrifuge model
- Whether the required part is still available
- Whether an authorized service provider can perform the repair
- The estimated cost and lead time for the part and service
It is also worth reviewing the centrifuge’s overall condition rather than focusing only on the immediate repair. Check the rotor, carriers, lid-lock mechanism, and control system, along with the equipment’s maintenance and repair history. Check for any wear or damage and follow the manufacturer’s recommendations for inspection and replacement.
A repair can sometimes address the current issue without resolving other concerns that could affect the centrifuge’s continued serviceability.
Decide Whether to Keep the Centrifuge or Replace It
Once you know what parts and service options remain available, weigh the repair against the longer-term needs of your operation.
Consider the following:
- Equipment condition: Are the rotor, lid-lock mechanism, controls, and other components in serviceable condition?
- Repair history: Has the centrifuge required frequent repairs, or is this an isolated issue?
- Parts and service support: Can the manufacturer or an authorized provider still supply necessary components and perform qualified repairs?
- Performance: Can the centrifuge continue to meet the requirements of your existing procedures?
- Downtime risk: If another component fails, how long could the centrifuge remain out of service while you look for parts or repair support?
If necessary parts or qualified repair are no longer available, replacement is often the more practical option. Even if the centrifuge is still operating, planning ahead can help avoid having to make an equipment decision in the middle of an unexpected failure.
Match a Replacement Centrifuge to Your Existing Procedures
Replacing a discontinued centrifuge involves more than finding a model with a similar appearance or maximum speed. The replacement needs to accommodate your existing tubes, rotor configuration requirements, and centrifugation conditions. Do not assume that rotors or accessories from the discontinued centrifuge are compatible with the new model.
Start by documenting how the current centrifuge is used:
- Specimen types: What samples do you process?
- Tube dimensions: Which tube sizes, volumes, and formats do your procedures require?
- Rotor and carriers: What rotor configuration and adapters are needed?
- Capacity: How many tubes need to be processed in a single run?
- Centrifugation settings: What relative centrifugal force (RCF or xg) and run time does each procedure require?
Compare RCF, Rotor Radius, and Run Time
One of the most important considerations when comparing centrifuges is the relationship between relative centrifugal force (RCF), rotor radius, and rotational speed (RPM).
RPM describes the rotor speed, while RCF describes the force applied to the sample. RCF depends on both rotational speed and rotor radius, so two centrifuges with different rotor radii operating at the same RPM would produce different RCF values. For that reason, matching RPM alone does not necessarily reproduce the same centrifugation conditions.
Eppendorf’s guidance on transferring centrifugation parameters recommends considering the sample, vessel, centrifuge, rotor, RCF, temperature, and running time. When using rotors with different radii, the article advises matching RCF rather than RPM. It also notes that adapters can change the effective rotor radius and the force applied to the sample.²
Check Tube and Reagent Requirements
Tube and reagent manufacturers may specify particular centrifugation conditions. Those instructions should be considered alongside your laboratory’s standard operating procedures (SOPs).
For example, BD provides different centrifugation recommendations for its blood collection tubes. Its guidance distinguishes between non-gel tubes, gel separator tubes, and Barricor™ plasma tubes, with settings that vary by tube type and, in some cases, rotor configuration.³
For routine blood specimens, CLSI PRE04 also addresses centrifugation and specimen quality, including the influence of collection tubes, additives, temperature, and the time and force applied during processing.⁴ These factors matter when evaluating whether a replacement centrifuge can support the procedures already in place.
Keep in mind that settings from a discontinued centrifuge won’t always transfer to a replacement. Review the applicable tube and reagent instructions, confirm the required rotor and accessories, and perform the equipment and process checks appropriate to your procedures before routine use.
Plan Ahead for Centrifuge Replacement
A discontinued centrifuge may continue to meet your needs, but limited access to parts and repair support can make future maintenance more difficult. Confirming the equipment’s support status, evaluating its condition, and documenting your existing procedures can help you make a more informed decision before a failure causes downtime.
Drucker Diagnostics can help review your existing tubes, cycles, and processing requirements to identify replacement centrifuge configurations that fit your existing workflows and applications. Contact our team at [email protected] or +1-866-265-1486 (US Toll-Free) to find the right upgrade for your lab.
Sources
- Miller JM, Astles R, Baszler T, et al. Guidelines for Safe Work Practices in Human and Animal Medical Diagnostic Laboratories. MMWR Suppl. 2012;61(Suppl 1).
- Eppendorf. Transferring Centrifugation Parameters From a Protocol to Your Own Conditions. Lab Academy.
- BD. BD Vacutainer Serum Tubes: Centrifugation Guidance for Common Blood Collection Tubes.
- Clinical and Laboratory Standards Institute. PRE04: Handling, Transport, Processing, and Storage of Blood Specimens for Routine Laboratory Examinations. 1st ed. 2023.