HORIZON 6 Flex

  • Max Speed (RPM): Up to 3800 RPM
  • Max Speed (RCF): Up to 2000 xg
  • Out of Box Capacity: 6 samples up to 10 mL
  • Dimensions (WxDxH): 12 x 14 x 9 in (30.5 x 35.6 x 22.9 cm)
  • Weight: 12 lbs (5.4 kg)
  • Warranty: 2 Years (Extended Available)
Now available internationally. Compact and customizable, the HORIZON 6 Flex gives you full control over cycle settings in a compact, user-friendly body. Its horizontal rotor spins up to six tubes and delivers consistent, high-quality separation every spin.

Ready to use, right out of the box

SKU: 00-376-009-000-EU Category:
Request a Quote

Ask your preferred distributor about purchasing the HORIZON 6 Flex (EU) , or call 1-866-265-1486 for volume pricing.

What makes it different?

  • Fits tight spaces with a compact footprint.
  • Shows cycle status at a glance with LED lid lighting.
  • Features 10 programmable settings for all your applications.

Preset Cycles

5 minutes / 1900 RPM / 500 xg

10 minutes / 3600 RPM / 1850 xg

15 minutes / 3300 RPM / 1500 xg

Applications

  • Blood Chemistry
  • Microtube Samples

Tubes Most Often Used

Lithium Heparin (With Gel), Lithium or Sodium Heparin (Without Gel), Serum (Without Gel), Serum Separator (With Gel), Sodium Citrate

Easy to Use

Use the simple, two-button interface to select a preset, or program and record your validated settings on the included label.

Easy to Monitor

Monitor time remaining down to the very last second on the digital display. LED lid lighting is off when the centrifuge is ready, on when running, and flashing at end of cycle.

Extended Coverage

All Drucker centrifuges are eligible for 1, 2, or 3-year extended warranty coverage. Purchase within 90 days of your original ship date to extend your protection.

The HORIZON 6 Flex is a compact, programmable centrifuge built for labs that need control and consistency in a smaller footprint. It holds six tubes up to 16 x 100 mm or 10 mL and reaches speeds up to 3,800 RPM (2,000 xg). Users can program custom settings for time, speed, g-force, and deceleration, or choose from three pre-set cycles. Backed by a two-year warranty, the HORIZON 6 Flex delivers reliable results in a flexible, space-saving design.

Centrifuges you can count on

Features

  • Tube Sizes: Up to 16 x 100 mm or 10 mL, Up to 10 x 46 mm or 2 mL (with adapter sold separately)
  • Out of Box Capacity: 6 samples up to 10 mL
  • Configurable Capacity: 6 samples up to 2 mL (with adapters sold separately)
  • Line Cords Available: Type B, Type E, Type F, Type G, Type H, Type I, Type J, Type L
  • Included Accessories: Carriers for 16 x 100 mm Tubes, Blue (6 qty) 7713079K
  • Swing-Out Horizontal: Drucker Diagnostics’ patented swing-out horizontal rotor design produces ideal horizontally separated samples
  • Clear Shattered Proof Lid: Allows for safe sample observation and optical calibrations
  • Reinforced Guard Bowl: Provides maximum safety and durability
  • Standard Warranty: 2-year standard warranty, extended warranties available for purchase within 90 days of original ship date

Specifications

  • Dimensions (WxDxH): 12 x 14 x 9 in (30.5 x 35.6 x 22.9 cm)
  • Weight: 12 lbs (5.4 kg)
  • Factory Settings Range: 1 to 30 Minutes (± 1%)
  • Voltage: 100 – 240 (+/- 10%) VAC
  • Certificates: ISO 13485:2016, General Purpose Laboratory Centrifuge (Self-Certified)

Frequently Asked Questions

Yes, Drucker Diagnostics offers a range of centrifuges for European markets, including general-purpose models and select clinical laboratory centrifuges that are compliant with IVD regulations.

Drucker Diagnostics provides a two (2) year parts and labor warranty. 1, 2, and 3-year extended warranties are available for purchase within 90 days of your centrifuge’s original ship date.

All of our centrifuges are sold complete with the rotor and tube holders. No additional accessories are necessary though there are additional options available for purchase.

Drucker Diagnostics recommends the centrifuge be calibrated every 2 years.

ONLY isopropyl alcohol, soap and water, or a 10% (5,500 PPM) bleach solution should be used for cleaning and disinfection of the centrifuge and accessories. The centrifuge must be unplugged and all surfaces must be dried immediately after cleaning and disinfecting.

TBQ Germicidal products should not be used as they will cause damage to the centrifuge and void the warranty. The use of fully/partially halogenated hydrocarbons, ketones, esters, ethers, benzyls, ethyl benzenes, and all other chemicals not prescribed by Drucker Diagnostics should not be used as they may cause damage to the rotor chamber, rotor, tube holders, accessories, and centrifuge exterior. If this occurs the warranty will be voided.