{"id":9780,"date":"2026-10-13T09:30:52","date_gmt":"2026-10-13T13:30:52","guid":{"rendered":"https:\/\/druckerdiagnostics.com\/resources\/blog\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\/"},"modified":"2026-10-22T14:15:11","modified_gmt":"2026-10-22T18:15:11","slug":"how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide","status":"publish","type":"post","link":"https:\/\/druckerdiagnostics.com\/en-gb\/resources\/blog\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\/","title":{"rendered":"How Many Centrifuges Does Your Laboratory Need? A Capacity Planning Guide"},"content":{"rendered":"<p><span style=\"font-weight: 400;\">When planning laboratory capacity, one of the most consequential equipment decisions you&#8217;ll make is determining centrifuge requirements. Yet most laboratories approach this question backwards\u2014calculating sample volume and then shopping for the largest single centrifuge they can afford, assuming bigger is always better for high-volume operations. <\/span><\/p>\n<p><b>TLDR:<\/b><span style=\"font-weight: 400;\"> Determining how many centrifuges your laboratory needs starts with understanding daily sample volume, peak demand periods, and test variety\u2014but the answer isn&#8217;t always &#8220;one bigger centrifuge.&#8221; Many high-volume clinical and veterinary laboratories achieve better throughput and operational resilience with multiple benchtop centrifuges working together rather than a single large floor-standing unit. This capacity planning guide helps you calculate your needs and choose the right configuration for your workflow.<\/span><\/p>\n<h2><b>Should you purchase one large centrifuge or multiple smaller units?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Before calculating how many centrifuges you need, answer this fundamental question: <\/span><b>Should you invest in one large, high-capacity centrifuge or multiple smaller benchtop units?<\/b><\/p>\n<p><span style=\"font-weight: 400;\">The conventional wisdom suggests high-volume laboratories need large floor-standing centrifuges. However, <\/span><b>most high-volume clinical and veterinary laboratories benefit more from distributed centrifuge capacity<\/b><span style=\"font-weight: 400;\"> than from a single centralised unit, even when processing 300+ samples daily.<\/span><\/p>\n<p><b>Why laboratories assume they need one large centrifuge:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">The assumption makes intuitive sense\u2014more volume requires more capacity. But this overlooks critical factors: <\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Workflow reality:<\/b><span style=\"font-weight: 400;\"> Most laboratories simultaneously run different test types requiring different centrifugation parameters, temperatures, and timing\u2014not uniform batches<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Single point of failure:<\/b><span style=\"font-weight: 400;\"> One centrifuge down means complete workflow shutdown<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Peak period bottlenecks:<\/b><span style=\"font-weight: 400;\"> Morning surges and STAT requests create queues, even with high-capacity units<\/span><\/li>\n<\/ul>\n<h2><b>What are the advantages of multiple benchtop centrifuges?<\/b><\/h2>\n<h3><b>Simultaneous Processing of Different Test Types<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Multiple benchtop units allow different protocols to run simultaneously. While one centrifuge processes chemistry samples at 8,500 RPM for 30 seconds, another handles STAT coagulation samples at 6,600 RPM for 3 minutes. No waiting, no workflow compromises.  <\/span><\/p>\n<h3><b>Operational Resilience and Redundancy<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">With multiple units, one centrifuge going down means reduced capacity, not complete shutdown. Preventive maintenance can be staggered across units without disrupting workflow. <\/span><\/p>\n<h3><b>Distributed Capacity Across Workstations<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Benchtop centrifuges can be positioned at each workstation or department. Haematology has their own unit, chemistry has theirs. Each area operates independently, eliminating queuing and reducing sample transport.  <\/span><\/p>\n<h3><b>Flexible Capacity Scaling<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Start with 2-3 benchtop units ($6,000-$18,000) and add capacity incrementally as volume grows. Each addition costs $3,000-$8,000, allowing you to match equipment investment to actual demand without over-committing. <\/span><\/p>\n<h3><b>Cost-Effective Capacity<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Three benchtop centrifuges with 2-litre capacity each provide similar total capacity to one 6-litre floor-standing unit, but cost $15,000-$20,000 combined versus $35,000 for the floor model\u2014saving 40-45% while gaining flexibility and redundancy.<\/span><\/p>\n<h2><b>When does a single large centrifuge make sense?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Certain situations genuinely benefit from a single high-capacity unit:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Blood banks<\/b><span style=\"font-weight: 400;\"> processing uniform blood bags in predictable batches<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Reference laboratories<\/b><span style=\"font-weight: 400;\"> running thousands of automated chemistry panels daily with limited test variety<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Research laboratories<\/b><span style=\"font-weight: 400;\"> requiring ultracentrifugation (&gt;20,000 RPM)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Smaller facilities<\/b><span style=\"font-weight: 400;\"> with limited capital budgets purchasing incrementally<\/span><\/li>\n<\/ul>\n<h2><b>What are warning signs you need more capacity?<\/b><\/h2>\n<p><b>Immediate indicators:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Technicians regularly wait for centrifuge availability<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Regular overtime to complete centrifugation runs<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Staff batches incompatible samples to maximise utilisation<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">STAT requests frequently interrupt routine batches<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Equipment maintenance forces workflow disruption<\/span><\/li>\n<\/ul>\n<p><b>These symptoms mean you&#8217;ve already waited too long.<\/b><span style=\"font-weight: 400;\"> Add capacity when volume reaches 75-80% of comfortable capacity, not when you hit 100%.<\/span><\/p>\n<h2><b>How should multiple centrifuges be configured?<\/b><\/h2>\n<h3><b>Small Clinic\/Veterinary Practice (50-100 samples\/day)<\/b><\/h3>\n<p><b>Configuration: 2 Benchtop Centrifuges<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Primary unit: 6-tube capacity, centrally located<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Secondary unit: Backup and specialty tests<\/span><\/li>\n<\/ul>\n<h3><b>Medium Clinical Laboratory (100-300 samples\/day)<\/b><\/h3>\n<p><b>Configuration: 3-4 Benchtop Centrifuges<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Haematology station: 12-tube capacity<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Chemistry station: 12-tube capacity<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">General station: 12-tube capacity<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Optional 4th: Backup\/specialty<\/span><\/li>\n<\/ul>\n<h3><b>High-Volume Laboratory (300-500 samples\/day)<\/b><\/h3>\n<p><b>Configuration: 4-6 Benchtop Centrifuges<\/b><\/p>\n<p><b>All-Benchtop Array:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">4-6 units distributed across workstations<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Mix of refrigerated and non-refrigerated<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">2-3 units for high-volume routine work<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">1-2 units for specialty\/overflow<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">1 unit as backup<\/span><\/li>\n<\/ul>\n<h3><b>Reference Laboratory (500+ samples\/day)<\/b><\/h3>\n<p><b>Configuration: 6-10 Centrifuges<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">2 floor-standing units for routine processing<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">4-6 benchtop units across specialty departments<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">2 units dedicated to STAT requests<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Remaining for specialty testing and redundancy<\/span><\/li>\n<\/ul>\n<h2><b>What factors beyond volume influence the decision?<\/b><\/h2>\n<h3><b>Test Menu Complexity<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">More diverse testing = more benefit from multiple units. Uniform protocols may work with fewer units. <\/span><\/p>\n<h3><b>Physical Layout<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Multi-room laboratories benefit from distributed capacity. Open floor plans may centralise multiple units side-by-side. <\/span><\/p>\n<h3><b>Staffing Model<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Multiple simultaneous technicians need multiple centrifuges. Single-person operations still need backup capacity. <\/span><\/p>\n<h3><b>Service Access<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Limited local service availability requires extra redundancy. Rural laboratories particularly need robust backup. <\/span><\/p>\n<h3><b>Regulatory Requirements<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">CLIA certification and CAP accreditation surveyors look for adequate capacity relative to volume. Backup equipment demonstrates strong quality management. <\/span><\/p>\n<h2><b>Common capacity planning mistakes<\/b><\/h2>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Mistake #1: Calculating at 100% utilisation<\/b><span style=\"font-weight: 400;\"> Practical capacity is 70-80% of theoretical maximum. Use 75% as maximum sustainable rate.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Mistake #2: Ignoring peak periods<\/b><span style=\"font-weight: 400;\"> Equipment must handle morning surges (typically 40-60% of daily volume in 2-3 hours), not just average daily flow.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Mistake #3: Overlooking protocol conflicts<\/b><span style=\"font-weight: 400;\"> Most blood chemistry samples need horizontal rotors for proper separation, while urine uses fixed-angle rotors. Different rotor types can&#8217;t run simultaneously. Calculate capacity for each protocol type separately.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Mistake #4: Underestimating redundancy needs<\/b><span style=\"font-weight: 400;\"> Plan for minimum 2 centrifuges even in small laboratories. One unit down shouldn&#8217;t halt operations.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Mistake #5: Buying for current volume only<\/b><span style=\"font-weight: 400;\"> Purchase capacity for projected volume 2-3 years out, or plan for incremental additions at defined milestones.<\/span><\/li>\n<\/ul>\n<h2><b>Key takeaways<\/b><\/h2>\n<h3><b>Challenge Conventional Assumptions<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Multiple benchtop centrifuges often outperform single large units for most clinical and veterinary laboratories, providing better throughput, flexibility, and operational resilience at 40-60% lower cost.<\/span><\/p>\n<h3><b>Calculate Realistically<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Use actual peak-period data, factor protocol conflicts, account for downtime, and add 30-50% buffer. Never plan for 100% utilisation. <\/span><\/p>\n<h3><b>Plan Proactively<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Add capacity when volume reaches 75-80% of comfortable capacity\u2014before workflow problems emerge. Establish specific triggers for capacity additions. <\/span><\/p>\n<h3><b>Configure Strategically<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Distribute centrifuges across workstations based on test types. Maintain at least one backup unit. Start with 2-3 units and add incrementally.  <\/span><\/p>\n<h3><b>Invest Wisely<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Total cost of ownership matters more than per-unit price. Multiple benchtop centrifuges typically cost 40-60% less than equivalent floor-standing capacity while providing superior flexibility. <\/span><\/p>\n<h2><b>How Drucker Diagnostics supports capacity planning<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Drucker Diagnostics specialises in benchtop centrifuges designed for clinical and veterinary laboratories. Our ready-to-use solutions support distributed capacity configurations: <\/span><\/p>\n<p><b>Product Lines:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>DASH Series:<\/b><span style=\"font-weight: 400;\"> STAT centrifuges<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>HORIZON Series:<\/b><span style=\"font-weight: 400;\"> Versatile general-purpose centrifuges<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>600 Series:<\/b><span style=\"font-weight: 400;\"> Compact, easy to use<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>TrueBond Series: <\/b><span style=\"font-weight: 400;\">Veterinary use<\/span><\/li>\n<\/ul>\n<p><b>Capacity Planning Support:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Workflow analysis and capacity calculations<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Equipment recommendations based on test menu and volume<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Configuration planning for distributed placements<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Service and support for multi-unit installations<\/span><\/li>\n<\/ul>\n<p><b>Ready to determine the right centrifuge capacity for your laboratory?<\/b><span style=\"font-weight: 400;\"> Contact Drucker Diagnostics to discuss your specific needs and explore how our benchtop centrifuge solutions can optimise your workflows.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>When planning laboratory capacity, one of the most consequential equipment decisions you&#8217;ll make is determining centrifuge requirements. Yet most laboratories approach this question backwards\u2014calculating sample volume and then shopping for the largest single centrifuge they can afford, assuming bigger is always better for high-volume operations. TLDR: Determining how many centrifuges your laboratory needs starts with [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":9439,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_searchwp_excluded":"","inline_featured_image":false,"footnotes":""},"categories":[1269,533],"tags":[],"application":[],"blog-type":[41],"product-family":[102,99,100,101,104],"market":[530],"class_list":["post-9780","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-clinical-lab","category-veterinary","blog-type-article","product-family-600-series","product-family-dash","product-family-horizon","product-family-sero","product-family-truebond","market-eu"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How Many Centrifuges Does Your Laboratory Need?<\/title>\n<meta name=\"description\" content=\"Calculate centrifuge needs for your clinical or veterinary laboratory. Learn why multiple benchtop units often outperform single large centrifuges for high-volume operations.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/druckerdiagnostics.com\/en-gb\/resources\/blog\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How Many Centrifuges Does Your Laboratory Need?\" \/>\n<meta property=\"og:description\" content=\"Calculate centrifuge needs for your clinical or veterinary laboratory. Learn why multiple benchtop units often outperform single large centrifuges for high-volume operations.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/druckerdiagnostics.com\/en-gb\/resources\/blog\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\/\" \/>\n<meta property=\"og:site_name\" content=\"Drucker Diagnostics\" \/>\n<meta property=\"article:published_time\" content=\"2026-10-13T13:30:52+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-22T18:15:11+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/druckerdiagnostics.com\/wp-content\/uploads\/2025\/07\/black-centrifuge-closeup-blue-caps.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2000\" \/>\n\t<meta property=\"og:image:height\" content=\"1333\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Amanda Wishner\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Amanda Wishner\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/resources\\\/blog\\\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/resources\\\/blog\\\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\\\/\"},\"author\":{\"name\":\"Amanda Wishner\",\"@id\":\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/#\\\/schema\\\/person\\\/a38eef84fe5bb68069fc62dca669c781\"},\"headline\":\"How Many Centrifuges Does Your Laboratory Need? A Capacity Planning Guide\",\"datePublished\":\"2026-10-13T13:30:52+00:00\",\"dateModified\":\"2026-10-22T18:15:11+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/resources\\\/blog\\\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\\\/\"},\"wordCount\":1096,\"publisher\":{\"@id\":\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/resources\\\/blog\\\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/druckerdiagnostics.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/black-centrifuge-closeup-blue-caps.jpg\",\"articleSection\":[\"Clinical Lab\",\"Veterinary\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/resources\\\/blog\\\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\\\/\",\"url\":\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/resources\\\/blog\\\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\\\/\",\"name\":\"How Many Centrifuges Does Your Laboratory Need?\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/resources\\\/blog\\\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/resources\\\/blog\\\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/druckerdiagnostics.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/black-centrifuge-closeup-blue-caps.jpg\",\"datePublished\":\"2026-10-13T13:30:52+00:00\",\"dateModified\":\"2026-10-22T18:15:11+00:00\",\"description\":\"Calculate centrifuge needs for your clinical or veterinary laboratory. Learn why multiple benchtop units often outperform single large centrifuges for high-volume operations.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/resources\\\/blog\\\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/resources\\\/blog\\\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/resources\\\/blog\\\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\\\/#primaryimage\",\"url\":\"https:\\\/\\\/druckerdiagnostics.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/black-centrifuge-closeup-blue-caps.jpg\",\"contentUrl\":\"https:\\\/\\\/druckerdiagnostics.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/black-centrifuge-closeup-blue-caps.jpg\",\"width\":2000,\"height\":1333,\"caption\":\"Black Centrifuge\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/resources\\\/blog\\\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How Many Centrifuges Does Your Laboratory Need? A Capacity Planning Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/#website\",\"url\":\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/\",\"name\":\"Drucker Diagnostics\",\"description\":\"Making people safer, healthier, and more productive, one centrifuge at a time.\",\"publisher\":{\"@id\":\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/#organization\",\"name\":\"Drucker Diagnostics\",\"url\":\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/druckerdiagnostics.com\\\/wp-content\\\/uploads\\\/2025\\\/06\\\/Logo.svg\",\"contentUrl\":\"https:\\\/\\\/druckerdiagnostics.com\\\/wp-content\\\/uploads\\\/2025\\\/06\\\/Logo.svg\",\"width\":369,\"height\":64,\"caption\":\"Drucker Diagnostics\"},\"image\":{\"@id\":\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/druckerdiagnostics.com\\\/en-gb\\\/#\\\/schema\\\/person\\\/a38eef84fe5bb68069fc62dca669c781\",\"name\":\"Amanda Wishner\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How Many Centrifuges Does Your Laboratory Need?","description":"Calculate centrifuge needs for your clinical or veterinary laboratory. Learn why multiple benchtop units often outperform single large centrifuges for high-volume operations.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/druckerdiagnostics.com\/en-gb\/resources\/blog\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\/","og_locale":"en_GB","og_type":"article","og_title":"How Many Centrifuges Does Your Laboratory Need?","og_description":"Calculate centrifuge needs for your clinical or veterinary laboratory. Learn why multiple benchtop units often outperform single large centrifuges for high-volume operations.","og_url":"https:\/\/druckerdiagnostics.com\/en-gb\/resources\/blog\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\/","og_site_name":"Drucker Diagnostics","article_published_time":"2026-10-13T13:30:52+00:00","article_modified_time":"2026-10-22T18:15:11+00:00","og_image":[{"width":2000,"height":1333,"url":"https:\/\/druckerdiagnostics.com\/wp-content\/uploads\/2025\/07\/black-centrifuge-closeup-blue-caps.jpg","type":"image\/jpeg"}],"author":"Amanda Wishner","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Amanda Wishner","Estimated reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/druckerdiagnostics.com\/en-gb\/resources\/blog\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\/#article","isPartOf":{"@id":"https:\/\/druckerdiagnostics.com\/en-gb\/resources\/blog\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\/"},"author":{"name":"Amanda Wishner","@id":"https:\/\/druckerdiagnostics.com\/en-gb\/#\/schema\/person\/a38eef84fe5bb68069fc62dca669c781"},"headline":"How Many Centrifuges Does Your Laboratory Need? A Capacity Planning Guide","datePublished":"2026-10-13T13:30:52+00:00","dateModified":"2026-10-22T18:15:11+00:00","mainEntityOfPage":{"@id":"https:\/\/druckerdiagnostics.com\/en-gb\/resources\/blog\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\/"},"wordCount":1096,"publisher":{"@id":"https:\/\/druckerdiagnostics.com\/en-gb\/#organization"},"image":{"@id":"https:\/\/druckerdiagnostics.com\/en-gb\/resources\/blog\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/druckerdiagnostics.com\/wp-content\/uploads\/2025\/07\/black-centrifuge-closeup-blue-caps.jpg","articleSection":["Clinical Lab","Veterinary"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/druckerdiagnostics.com\/en-gb\/resources\/blog\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\/","url":"https:\/\/druckerdiagnostics.com\/en-gb\/resources\/blog\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\/","name":"How Many Centrifuges Does Your Laboratory Need?","isPartOf":{"@id":"https:\/\/druckerdiagnostics.com\/en-gb\/#website"},"primaryImageOfPage":{"@id":"https:\/\/druckerdiagnostics.com\/en-gb\/resources\/blog\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\/#primaryimage"},"image":{"@id":"https:\/\/druckerdiagnostics.com\/en-gb\/resources\/blog\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/druckerdiagnostics.com\/wp-content\/uploads\/2025\/07\/black-centrifuge-closeup-blue-caps.jpg","datePublished":"2026-10-13T13:30:52+00:00","dateModified":"2026-10-22T18:15:11+00:00","description":"Calculate centrifuge needs for your clinical or veterinary laboratory. Learn why multiple benchtop units often outperform single large centrifuges for high-volume operations.","breadcrumb":{"@id":"https:\/\/druckerdiagnostics.com\/en-gb\/resources\/blog\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/druckerdiagnostics.com\/en-gb\/resources\/blog\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/druckerdiagnostics.com\/en-gb\/resources\/blog\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\/#primaryimage","url":"https:\/\/druckerdiagnostics.com\/wp-content\/uploads\/2025\/07\/black-centrifuge-closeup-blue-caps.jpg","contentUrl":"https:\/\/druckerdiagnostics.com\/wp-content\/uploads\/2025\/07\/black-centrifuge-closeup-blue-caps.jpg","width":2000,"height":1333,"caption":"Black Centrifuge"},{"@type":"BreadcrumbList","@id":"https:\/\/druckerdiagnostics.com\/en-gb\/resources\/blog\/how-many-centrifuges-does-your-laboratory-need-a-capacity-planning-guide\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/druckerdiagnostics.com\/en-gb\/"},{"@type":"ListItem","position":2,"name":"How Many Centrifuges Does Your Laboratory Need? A Capacity Planning Guide"}]},{"@type":"WebSite","@id":"https:\/\/druckerdiagnostics.com\/en-gb\/#website","url":"https:\/\/druckerdiagnostics.com\/en-gb\/","name":"Drucker Diagnostics","description":"Making people safer, healthier, and more productive, one centrifuge at a time.","publisher":{"@id":"https:\/\/druckerdiagnostics.com\/en-gb\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/druckerdiagnostics.com\/en-gb\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/druckerdiagnostics.com\/en-gb\/#organization","name":"Drucker Diagnostics","url":"https:\/\/druckerdiagnostics.com\/en-gb\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/druckerdiagnostics.com\/en-gb\/#\/schema\/logo\/image\/","url":"https:\/\/druckerdiagnostics.com\/wp-content\/uploads\/2025\/06\/Logo.svg","contentUrl":"https:\/\/druckerdiagnostics.com\/wp-content\/uploads\/2025\/06\/Logo.svg","width":369,"height":64,"caption":"Drucker Diagnostics"},"image":{"@id":"https:\/\/druckerdiagnostics.com\/en-gb\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/druckerdiagnostics.com\/en-gb\/#\/schema\/person\/a38eef84fe5bb68069fc62dca669c781","name":"Amanda Wishner"}]}},"_links":{"self":[{"href":"https:\/\/druckerdiagnostics.com\/en-gb\/wp-json\/wp\/v2\/posts\/9780","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/druckerdiagnostics.com\/en-gb\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/druckerdiagnostics.com\/en-gb\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/druckerdiagnostics.com\/en-gb\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/druckerdiagnostics.com\/en-gb\/wp-json\/wp\/v2\/comments?post=9780"}],"version-history":[{"count":0,"href":"https:\/\/druckerdiagnostics.com\/en-gb\/wp-json\/wp\/v2\/posts\/9780\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/druckerdiagnostics.com\/en-gb\/wp-json\/wp\/v2\/media\/9439"}],"wp:attachment":[{"href":"https:\/\/druckerdiagnostics.com\/en-gb\/wp-json\/wp\/v2\/media?parent=9780"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/druckerdiagnostics.com\/en-gb\/wp-json\/wp\/v2\/categories?post=9780"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/druckerdiagnostics.com\/en-gb\/wp-json\/wp\/v2\/tags?post=9780"},{"taxonomy":"application","embeddable":true,"href":"https:\/\/druckerdiagnostics.com\/en-gb\/wp-json\/wp\/v2\/application?post=9780"},{"taxonomy":"blog-type","embeddable":true,"href":"https:\/\/druckerdiagnostics.com\/en-gb\/wp-json\/wp\/v2\/blog-type?post=9780"},{"taxonomy":"product-family","embeddable":true,"href":"https:\/\/druckerdiagnostics.com\/en-gb\/wp-json\/wp\/v2\/product-family?post=9780"},{"taxonomy":"market","embeddable":true,"href":"https:\/\/druckerdiagnostics.com\/en-gb\/wp-json\/wp\/v2\/market?post=9780"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}